Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 16.437
Filtrar
1.
J Refract Surg ; 40(4): e253-e259, 2024 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-38593262

RESUMO

PURPOSE: To compare simulated keratometry (SimK) and total corneal power (TCP) in keratoconic eyes, to determine whether the differences are systematic and predictable and to evaluate an adjusted TCP-based formula for intraocular lens (IOL) power calculation. METHODS: In a consecutive series of keratoconic eyes, measurements of SimK, TCP, posterior keratometry, and anterior and posterior corneal asphericities (Q-values) were retrospectively collected. The difference between SimK and TCP was linearly correlated to the biometric parameters. In a separate sample of keratoconic eyes that had undergone cataract surgery, IOL power was calculated with the Barrett Universal II, Hoffer QST, Holladay 1, Kane, and SRK/T formulas using the SimK and an adjusted TCP power. The respective prediction errors were calculated. RESULTS: A total of 382 keratoconic eyes (271 patients) were enrolled. An increasing overestimation of SimK by TCP was detected from stage I to III, with a significant correlation between the SimK and TCP difference and SimK in the whole sample (P < .0001, r2 = 0.1322). Approximately 7% of cases presented an underestimation of SimK by TCP. IOL power calculation with the adjusted TCP improved outcomes, achieving a maximum of 80% of eyes with a prediction error within ±0.50 diopters with the Hoffer QST, Holladay 1, and Kane formulas. CONCLUSIONS: Overall, SimK overestimated TCP. Such a difference could not be predicted by any variable. The proposed TCP-adjustment formula (TCPadj = TCP + 0.56 diopters) in keratoconic eyes for IOL power calculation might be valuable for improving refractive outcomes. [J Refract Surg. 2024;40(4):e253-e259.].


Assuntos
Ceratocone , Lentes Intraoculares , Facoemulsificação , Humanos , Ceratocone/diagnóstico , Implante de Lente Intraocular/métodos , Estudos Retrospectivos , Facoemulsificação/métodos , Óptica e Fotônica , Refração Ocular , Biometria/métodos
2.
Biosens Bioelectron ; 254: 116231, 2024 Jun 15.
Artigo em Inglês | MEDLINE | ID: mdl-38513540

RESUMO

Strong light-matter coupling between molecules and electromagnetic field lead to the formation of hybrid polaritonic states for surface enhanced Raman scattering (SERS) detection. However, owing to the inefficient interaction between zero-point fluctuations of photons/plasmons and molecular electronic transitions, the Raman enhancement is limited in relative low levels. Here, we propose and fabricate a TiOx/Cu2-xSe/R6G nanocavity based photonic-plasmonic-polaritonic resonator for single molecular SERS detection. Through precisely matching the energy levels of illuminated photon, generated plasmon, and molecular polariton, an extremely high Raman enhancement factor of 2.6 × 109 is implemented. The rationally designed SERS substrate allows sensitive detection of miRNA-21 in single molecular level with a detection limit of 1.58 aM. The hybrid SERS mechanism both from electromagnetic and chemical perspectives in this photonic-plasmonic-polaritonic resonance strategy provides insight into polaritonic semiconductor systems, thus paving the way for new experimental possibilities in light-matter hybrids.


Assuntos
Técnicas Biossensoriais , MicroRNAs , Nanotecnologia , Óptica e Fotônica , Análise Espectral Raman
3.
Comput Biol Med ; 173: 108245, 2024 May.
Artigo em Inglês | MEDLINE | ID: mdl-38531253

RESUMO

PURPOSE: This study aimed to evaluate and optimize intraocular lens (IOL) power selection for cataract patients with high axial myopia receiving trifocal IOLs. DESIGN: A multi-center, retrospective observational case series was conducted. Patients having an axial length ≥26 mm and undergoing cataract surgery with trifocal IOL implanted were studied. METHODS: Preoperative biometric and postoperative outcome data from 139 eyes were collected to train and test various machine learning (ML) models (support vector machine, linear regression, and stacking regressor) using five-fold cross-validation. The models' performance was further validated externally using data from 48 eyes enrolled from other hospitals. Performance of seven IOL calculation formulas (BUII, Kane, EVO, K6, DGS, Holladay I, and SRK/T) were examined with and without ML models. RESULTS: The results of cross-validation revealed improvements across all IOL calculation formulas, especially for K6 and Holladay I. The model increased the percentage of eyes with a prediction error (PE) within ±0.50 D from 71.94% to 79.14% for K6, and from 35.25% to 51.80% for Holladay I. In external validation involving 48 patients from other centers, six out of seven formulas demonstrated a reduction in the mean absolute error (MAE). K6's PE within ±0.50 D improved from 62.50% to 77.08%, and Holladay I from 16.67% to 58.33%. CONCLUSIONS: In this study, we conducted a comprehensive evaluation of seven IOL power calculation formulas in high axial myopia cases and explored the effectiveness of the Stacking Regressor model in augmenting their accuracy. Of these formulas, K6 and Holladay I exhibited the most significant improvements, suggesting that integrating ML may have varying levels of effectiveness across different formulas but holds substantial promise in improving the predictability of IOL power calculations in patients with long eyes.


Assuntos
Catarata , Lentes Intraoculares , Miopia , Humanos , Refração Ocular , Estudos Retrospectivos , Miopia/cirurgia , Óptica e Fotônica
4.
Sci Rep ; 14(1): 6343, 2024 03 15.
Artigo em Inglês | MEDLINE | ID: mdl-38491195

RESUMO

The in vivo diagnosis and monitoring of pulmonary disorders (caused for example by emphysema, Covid-19, immature lung tissue in infants) could be effectively supported by the non-invasive sensing of the lung through light. With this purpose, we investigated the feasibility of probing the lung by means of time-resolved diffuse optics, leveraging the increased depth (a few centimeters) attained by photons collected after prolonged propagation time (a few nanoseconds). We present an initial study that includes measurements performed on 5 healthy volunteers during a breathing protocol, using a time-resolved broadband diffuse optical spectroscopy system. Those measurements were carried out across the spectral range of 600-1100 nm at a source-detector distance of 3 cm, and at 820 nm over a longer distance (7-9 cm). The preliminary analysis of the in vivo data with a simplified homogeneous model revealed a maximum probing depth of 2.6-3.9 cm, suitable for reaching the lung. Furthermore, we observed variations in signal associated with respiration, particularly evident at long photon propagation times. However, challenges stemming from both intra- and inter-subject variability, along with inconsistencies potentially arising from conflicting scattering and absorption effects on the collected signal, hindered a clear interpretation. Aspects that require further investigation for a more comprehensive understanding are outlined.


Assuntos
Óptica e Fotônica , Fótons , Humanos , Análise Espectral/métodos , Pulmão/diagnóstico por imagem
5.
J Biomed Opt ; 29(3): 036502, 2024 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-38515831

RESUMO

Significance: The reprojection setup typical of oblique plane microscopy (OPM) limits the effective aperture of the imaging system, and therefore its efficiency and resolution. Large aperture system is only possible through the use of custom specialized optics. A full-aperture OPM made with off the shelf components would both improve the performance of the method and encourage its widespread adoption. Aim: To prove the feasibility of an OPM without a conventional reprojection setup, retaining the full aperture of the primary objective employed. Approach: A deformable lens based remote focusing setup synchronized with the rolling shutter of a complementary metal-oxide semiconductor detector is used instead of a traditional reprojection system. Results: The system was tested on microbeads, prepared slides, and zebrafish embryos. Resolution and pixel throughput were superior to conventional OPM with cropped apertures, and comparable with OPM implementations with custom made optical components. Conclusions: An easily reproducible approach to OPM imaging is presented, eliminating the conventional reprojection setup and exploiting the full aperture of the employed objective.


Assuntos
Lentes , Dispositivos Ópticos , Animais , Microscopia/métodos , Peixe-Zebra , Óptica e Fotônica , Óxidos
6.
Ophthalmic Res ; 67(1): 248-256, 2024.
Artigo em Inglês | MEDLINE | ID: mdl-38527448

RESUMO

INTRODUCTION: This study aimed to determine the interchangeability of bilateral anterior chamber depth (ACD) in intraocular lens (IOL) power calculations for cataractous eyes and refractive outcomes using the unaffected fellow eye's ACD in subluxated crystalline lenses. METHODS: The predicted postoperative spherical equivalent (SE) calculated using the Kane formula with and without fellow eye's ACD in 202 cataract patients was compared. Refractive outcomes of the newer formulas (the Kane, Barrett Universal II [BUII], and Pearl-DGS formulas) with affected eye's ACD and with unaffected fellow eye's ACD were compared in 33 eyes with lens subluxation (the affected eye) undergoing in-the-bag IOL implantation. The SD of the prediction error (PE) was assessed using the heteroscedastic method. RESULTS: In 202 paired cataractous eyes, no marked ACD difference was found bilaterally; the predicted SE obtained without the fellow eye's ACD was comparable with that calculated with the fellow eye one (p = 0.90), with a mean absolute difference of 0.03 ± 0.03 D. With the affected eye AL, keratometry, and ACD, the median absolute error (MedAE) was 0.38-0.64 D, and the percentage of PE within ±0.50 D was 30.30-57.58%. The unaffected eye's ACD improved the results (MedAE, 0.35-0.49 D; the percentage of PE within ±0.50 D, 54.55-63.64%). The SDs of the BUII (0.82 D) and Pearl-DGS formulas (0.87 D) with the affected eye's ACD were significantly larger than those of the Kane and Pearl-DGS formulas (both 0.69 D) with the unaffected eye's ACD. CONCLUSION: Bilateral ACD was interchangeable in IOL power calculation for cataractous eyes when using the Kane formula. Unaffected eye's ACD in lieu of affected eye's ACD can enhance the accuracy of newer formulas in patients with unilateral subluxated lenses undergoing in-the-bag IOL implantation.


Assuntos
Câmara Anterior , Subluxação do Cristalino , Lentes Intraoculares , Refração Ocular , Humanos , Masculino , Feminino , Idoso , Refração Ocular/fisiologia , Pessoa de Meia-Idade , Subluxação do Cristalino/cirurgia , Subluxação do Cristalino/diagnóstico , Subluxação do Cristalino/fisiopatologia , Adulto , Acuidade Visual , Estudos Retrospectivos , Óptica e Fotônica , Implante de Lente Intraocular/métodos , Biometria/métodos , Idoso de 80 Anos ou mais
7.
BMC Ophthalmol ; 24(1): 126, 2024 Mar 19.
Artigo em Inglês | MEDLINE | ID: mdl-38504225

RESUMO

BACKGROUND: This study evaluates the impact of corneal power on the accuracy of 14 newer intraocular lens (IOL) calculation formulas in cataract surgery. The aim is to assess how these formulas perform across different corneal curvature ranges, thereby guiding more precise IOL selection. METHODS: In this retrospective case series, 336 eyes from 336 patients who underwent cataract surgery were studied. The cohort was divided into three groups according to preoperative corneal power. Key metrics analyzed included mean prediction error (PE), standard deviation of PE (SD), mean absolute prediction error (MAE), median absolute error (MedAE), and the percentage of eyes with PE within ± 0.25 D, 0.50 D, ± 0.75 D, ± 1.00 D and ± 2.00 D. RESULTS: In the flat K group (Km < 43 D), VRF-G, Emmetropia Verifying Optical Version 2.0 (EVO2.0), Kane, and Hoffer QST demonstrated lower SDs (± 0.373D, ± 0.379D, ± 0.380D, ± 0.418D, respectively) compared to the VRF formula (all P < 0.05). EVO2.0 and K6 showed significantly different SDs compared to Barrett Universal II (BUII) (all P < 0.02). In the medium K group (43 D ≤ Km < 46 D), VRF-G, BUII, Karmona, K6, EVO2.0, Kane, and Pearl-DGS recorded lower MAEs (0.307D to 0.320D) than Olsen (OLCR) and Castrop (all P < 0.03), with RBF3.0 having the second lowest MAE (0.309D), significantly lower than VRF and Olsen (OLCR) (all P < 0.05). In the steep K group (Km ≥ 46D), RBF3.0, K6, and Kane achieved significantly lower MAEs (0.279D, 0.290D, 0.291D, respectively) than Castrop (all P < 0.001). CONCLUSIONS: The study highlights the varying accuracy of newer IOL formulas based on corneal power. VRF-G, EVO2.0, Kane, K6, and Hoffer QST are highly accurate for flat corneas, while VRF-G, RBF3.0, BUII, Karmona, K6, EVO2.0, Kane, and Pearl-DGS are recommended for medium K corneas. In steep corneas, RBF3.0, K6, and Kane show superior performance.


Assuntos
Extração de Catarata , Catarata , Lentes Intraoculares , Facoemulsificação , Humanos , Estudos Retrospectivos , Córnea , Olho Artificial , Biometria , Refração Ocular , Óptica e Fotônica , Comprimento Axial do Olho
8.
Cells ; 13(5)2024 Feb 29.
Artigo em Inglês | MEDLINE | ID: mdl-38474397

RESUMO

This Editorial is the preface for the topical collection of "Computational Imaging for Biophotonics and Biomedicine", which collates the 12 contributions listed in Table 1 [...].


Assuntos
Óptica e Fotônica
9.
J Refract Surg ; 40(3): e156-e163, 2024 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-38466761

RESUMO

PURPOSE: To assess the performance of the Camellin-Calossi formula in eyes with prior myopic laser vision correction. METHODS: This was a retrospective case series. Patients included had a history of uncomplicated myopic laser vision correction and cataract surgery. The primary outcome measures were cumulative distribution of absolute refractive prediction error, absolute refractive prediction error, and refractive prediction error. These parameters were estimated post-hoc using the Camellin-Calossi, Shammas, Haigis-L, Barrett True-K with or without history, Masket, and Modified Masket formulas and their averages starting from biometric data, clinical records, postoperative refraction, and intraocular lens power implanted. RESULTS: Seventy-seven eyes from 77 patients were included. The Camellin-Calossi, Shammas, Haigis-L, Barrett True-K No History, Masket, Modified Masket, and Barrett True-K formulas showed a median absolute refractive error (interquartile range) of 0.25 (0.53), 0.51 (0.56), 0.44 (0.65), 0.45 (0.59), 0.40 (0.61), 0.60 (0.70), and 0.55 (0.76), respectively. The proportion of eyes with an absolute refractive error of ±0.25, 0.50, 0.75, 1.00, 1.50, and 2.00 diopters (D) for the Camellin-Calossi formula was 54.5%, 72.7%, 85.7%, 92.2%, 98.7%, and 100%, respectively. The cumulative distribution of the Camellin-Calossi formula showed the best qualitative performances when compared to the others. A statistically significant difference was identified with all of the others except the Haigis-L using a threshold of 0.25, with the Shammas, Modified Masket, and Barrett True-K at a threshold of 0.50 D and the Barrett True-K and Modified Masket at a threshold of 1.00 D. CONCLUSIONS: The Camellin-Calossi formula is a valid option for intraocular lens power calculation in eyes with prior myopic laser vision correction. [J Refract Surg. 2024;40(3):e156-e163.].


Assuntos
Ceratomileuse Assistida por Excimer Laser In Situ , Lentes Intraoculares , Miopia , Facoemulsificação , Humanos , Implante de Lente Intraocular , Estudos Retrospectivos , Refração Ocular , Miopia/cirurgia , Biometria , Lasers , Óptica e Fotônica
10.
Sci Rep ; 14(1): 4462, 2024 02 23.
Artigo em Inglês | MEDLINE | ID: mdl-38396107

RESUMO

This study evaluated the accuracy of newer formulas (Barrett Universal II, EVO 2.0, Kane, Hoffer QST, and PEARL-DGS) and the Haigis formula in Korean patients with the Alcon TFNT multifocal intraocular lens. In total, 3100 randomly selected eyes of 3100 patients were retrospectively reviewed. After constant optimization, the standard deviation (SD) of the prediction error was assessed for the entire group, and the root mean square error was compared for short and long axial length (AL) subgroup analysis. The Cooke-modified AL (CMAL) was experimentally applied to the Haigis formula. All the newer formulas performed well, but they did not significantly outperform the Haigis formula. In addition, all the newer formulas exhibited significant myopic outcomes (- 0.23 to - 0.29 diopters) in long eyes. Application of the CMAL to the Haigis formula with single constant optimization produced similar behavior and higher correlation with the newer formulas. The CMAL-applied triple-optimized Haigis formula yielded a substantially smaller SD, even superior to the Barrett and Hoffer QST formulas. The AL modification algorithms such as the CMAL used in newer formulas to cope with optical biometry's overestimation of the AL in long eyes seemed to overcompensate, particularly in the long eyes of the East Asian population.


Assuntos
Lentes Intraoculares , Lentes Intraoculares Multifocais , Facoemulsificação , Humanos , Estudos Retrospectivos , Refração Ocular , Implante de Lente Intraocular , Biometria , Óptica e Fotônica , Comprimento Axial do Olho , República da Coreia
11.
Sci Rep ; 14(1): 4611, 2024 02 26.
Artigo em Inglês | MEDLINE | ID: mdl-38409314

RESUMO

This study aimed to establish a virtual cross cylinder method to calculate the total corneal astigmatism by combining the anterior and posterior corneal astigmatism on the secondary principal plane of the cornea based on Gaussian optics. The meridian with the least refractive power, namely, the flattest meridian of the virtual cross cylinder of a ± 0.5 × C diopter, is set as the reference meridian, and the power (F) at an angle of φ between an arbitrary meridian and the reference meridian is defined as F(φ) = - 0.5 × C × cos2φ. The magnitude and axis of the total corneal astigmatism were calculated by applying trigonometric functions and the atan2 function based on the combination of the virtual cross cylinders of the anterior corneal astigmatism and the posterior corneal astigmatism. To verify the performance of the virtual cross cylinder method, a verification experiment with two Jackson cross cylinders and a lensmeter was performed, and the measured and calculated values were compared. The limit of the natural domain of the arctangent function is circumvented by using the atan2 function. The magnitude and axis of the total corneal astigmatism are determined through generalized mathematical expressions. The verification experiment results showed good agreement between the measured and calculated values. Compared to the vector analysis method, the virtual cross cylinder method is mathematically sound and straightforward. A novel technique for calculating total corneal astigmatism, the virtual cross cylinder method, was developed and verified.


Assuntos
Astigmatismo , Doenças da Córnea , Humanos , Astigmatismo/diagnóstico , Córnea , Óptica e Fotônica , Distribuição Normal , Topografia da Córnea , Refração Ocular
12.
Nat Commun ; 15(1): 1031, 2024 Feb 03.
Artigo em Inglês | MEDLINE | ID: mdl-38310087

RESUMO

The advance of genetic function indicators has enabled the observation of neuronal activities at single-cell resolutions. A major challenge for the applications on mammalian brains is the limited optical access depth. Currently, the method of choice to access deep brain structures is to insert miniature optical components. Among these validated miniature optics, the gradient-index (GRIN) lens has been widely employed for its compactness and simplicity. However, due to strong fourth-order astigmatism, GRIN lenses suffer from a small imaging field of view, which severely limits the measurement throughput and success rate. To overcome these challenges, we developed geometric transformation adaptive optics (GTAO), which enables adaptable achromatic large-volume correction through GRIN lenses. We demonstrate its major advances through in vivo structural and functional imaging of mouse brains. The results suggest that GTAO can serve as a versatile solution to enable large-volume recording of deep brain structures and activities through GRIN lenses.


Assuntos
Cristalino , Lentes , Camundongos , Animais , Óptica e Fotônica , Encéfalo/diagnóstico por imagem , Neuroimagem , Mamíferos
13.
Nature ; 627(8002): 80-87, 2024 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-38418888

RESUMO

Integrated microwave photonics (MWP) is an intriguing technology for the generation, transmission and manipulation of microwave signals in chip-scale optical systems1,2. In particular, ultrafast processing of analogue signals in the optical domain with high fidelity and low latency could enable a variety of applications such as MWP filters3-5, microwave signal processing6-9 and image recognition10,11. An ideal integrated MWP processing platform should have both an efficient and high-speed electro-optic modulation block to faithfully perform microwave-optic conversion at low power and also a low-loss functional photonic network to implement various signal-processing tasks. Moreover, large-scale, low-cost manufacturability is required to monolithically integrate the two building blocks on the same chip. Here we demonstrate such an integrated MWP processing engine based on a 4 inch wafer-scale thin-film lithium niobate platform. It can perform multipurpose tasks with processing bandwidths of up to 67 GHz at complementary metal-oxide-semiconductor (CMOS)-compatible voltages. We achieve ultrafast analogue computation, namely temporal integration and differentiation, at sampling rates of up to 256 giga samples per second, and deploy these functions to showcase three proof-of-concept applications: solving ordinary differential equations, generating ultra-wideband signals and detecting edges in images. We further leverage the image edge detector to realize a photonic-assisted image segmentation model that can effectively outline the boundaries of melanoma lesion in medical diagnostic images. Our ultrafast lithium niobate MWP engine could provide compact, low-latency and cost-effective solutions for future wireless communications, high-resolution radar and photonic artificial intelligence.


Assuntos
Micro-Ondas , Nióbio , Óptica e Fotônica , Óxidos , Fótons , Inteligência Artificial , Diagnóstico por Imagem/instrumentação , Diagnóstico por Imagem/métodos , Melanoma/diagnóstico por imagem , Melanoma/patologia , Óptica e Fotônica/instrumentação , Óptica e Fotônica/métodos , Radar , Tecnologia sem Fio , Humanos
14.
Sci Rep ; 14(1): 4228, 2024 02 20.
Artigo em Inglês | MEDLINE | ID: mdl-38378801

RESUMO

This study evaluates the accuracy of a newly developed intraocular lens (IOL) power calculation method that applies four different IOL power calculation formulas according to 768 biometric subgroups based on keratometry, anterior chamber depth, and axial length. This retrospective cross-sectional study was conducted in at Korea University Ansan Hospital. A total of 1600 eyes from 1600 patients who underwent phacoemulsification and a ZCB00 IOL in-the-bag implantation were divided into two datasets: a reference dataset (1200 eyes) and a validation dataset (400 eyes). Using the reference dataset and the results of previous studies, the Eom IOL power calculator was developed using 768 biometric subgroups. The median absolute errors (MedAEs) and IOL Formula Performance Indexes (FPIs) of the Barrett Universal II, Haigis, Hoffer Q, Holladay 1, Ladas Super, SRK/T, and Eom formulas using the 400-eye validation dataset were compared. The MedAE of the Eom formula (0.22 D) was significantly smaller than that of the other four formulas, except for the Barrett Universal II and Ladas Super formulas (0.24 D and 0.23 D, respectively). The IOL FPI of the Eom formula was 0.553, which ranked first, followed by the Ladas Super (0.474), Barrett Universal II (0.470), Holladay 1 (0.444), Hoffer Q (0.396), Haigis (0.392), and SRK/T (0.361) formulas. In conclusion, the Eom IOL power calculator developed in this study demonstrated similar or slightly better accuracy than the Barrett Universal II and Ladas Super formulas and was superior to the four traditional IOL power calculation formulas.


Assuntos
Lentes Intraoculares , Facoemulsificação , Humanos , Refração Ocular , Acuidade Visual , Estudos Retrospectivos , Estudos Transversais , Comprimento Axial do Olho , Facoemulsificação/métodos , Biometria/métodos , Óptica e Fotônica
15.
Opt Express ; 32(2): 2631-2643, 2024 Jan 15.
Artigo em Inglês | MEDLINE | ID: mdl-38297787

RESUMO

Among various specifications of near eye display (NED) devices, a compact formfactor is essential for comfortable user experience but also the hardest one to accomplish due to the slowest progresses. A pinhole/pinlight array based light-field (LF) technique is considered as one of the candidates to achieve that goal without thicker and heavier refractive optics. Despite those promising advantages, however, there are critical issues, such as dark spots and contrast distortion, which degrade the image quality because of the vulnerability of the LF retinal image when the observer's eye pupil size changes. Regardless of previous attempts to overcome those artifacts, it was impossible to resolve both issues due to their trade-off relation. In this paper, in order to resolve them simultaneously, we propose a concept of multiplexed retinal projections to integrate the LF retinal image through rotating transitions of refined and modulated elemental images for robust compensation of eye pupil variance with improved conservation of contrast distribution. Experimental demonstrations and quantitative analysis are also provided to verify the principle.


Assuntos
Pupila , Retina , Refração Ocular , Óptica e Fotônica , Estimulação Luminosa
16.
Curr Eye Res ; 49(5): 477-486, 2024 May.
Artigo em Inglês | MEDLINE | ID: mdl-38251647

RESUMO

PURPOSE: To evaluate prediction accuracy of pre- and post-DMEK keratometry (K) and total keratometry (TK) values for IOL power calculations in Fuchs endothelial corneal dystrophy (FECD) eyes undergoing DMEK with cataract surgery (triple DMEK). METHODS: Retrospective cross-sectional multicenter study of 55 FECD eyes (44 patients) that underwent triple DMEK between 2019 and 2022 between two centers in USA and Europe. Swept-source optical coherence tomography biometry (IOLMaster 700) was used for pre- and post-DMEK measurements. K and TK values were used for power calculations with ten formulae (Barrett Universal II (BUII), Castrop, Cooke K6, EVO 2.0, Haigis, Hoffer Q, Hoffer QST, Holladay I, Kane, and SRK/T). Mean error, mean absolute error (MAE), standard deviation, and percentage of eyes within ±0.50/±1.00 diopters (D) were calculated. Studied formulae were additionally adjusted using a method published previously (IOLup1D Method), which increases the IOL power by 1D. While both eyes from the same patient were considered for descriptive statistics, we restricted to one eye per individual (44 eyes for statistical comparisons. RESULTS: MAEs for all formulae were lower for post-DMEK K and TK than pre-DMEK K and TK by an average of 0.24 and 0.47 D, respectively. The lowest MAE was 0.49 D for Kane using post-DMEK TK, and the highest MAE was 1.05 D for BUII using pre-DMEK TK. Most IOLup1D formulae had lower MAEs than pre-DMEK K and TK formulae. CONCLUSIONS: The IOLup1D Method should be used instead of pre-DMEK K and TK values for triple DMEK in FECD eyes. Using post-DMEK TK values for cataract surgery after DMEK provides better refractive accuracy than any of the three studied methods used for triple DMEK procedures.


Assuntos
Catarata , Lentes Intraoculares , Facoemulsificação , Humanos , Implante de Lente Intraocular , Estudos Retrospectivos , Estudos Transversais , Refração Ocular , Biometria/métodos , Óptica e Fotônica
17.
J Cataract Refract Surg ; 50(5): 492-497, 2024 May 01.
Artigo em Inglês | MEDLINE | ID: mdl-38237070

RESUMO

PURPOSE: To investigate the difference between the segmented axial length (AL) and the composite AL on a swept-source optical coherence tomography biometer and to evaluate the subsequent effects on artificial intelligence intraocular lens (IOL) power calculations: the Kane and Hill-RBF 3.0 formulas compared with established vergence formulas. SETTING: National Hospital Organization, Tokyo Medical Center, Japan. DESIGN: Retrospective case series. METHODS: Consecutive patients undergoing cataract surgery with a single-piece IOL were reviewed. The prediction accuracy of the Barrett Universal II, Haigis, Hill-RBF 3.0, Hoffer Q, Holladay 1, Kane, and SRK/T formulas based on 2 ALs were compared for each formula. The heteroscedastic test was used with the SD of prediction errors as the endpoint for formula performance. RESULTS: The study included 145 eyes of 145 patients. The segmented AL (24.83 ± 1.89) was significantly shorter than the composite AL (24.88 ± 1.96, P < .001). Bland-Altman analysis revealed a negative proportional bias for the differences between the segmented AL and the composite AL. The SD values obtained by Hoffer Q, Holladay 1, and SRK/T formulas based on the segmented AL (0.52 diopters [D], 0.54 D, and 0.50 D, respectively) were significantly lower than those based on the composite AL (0.57 D, 0.60 D, and 0.52 D, respectively, P < .01). CONCLUSIONS: The segmented ALs were longer in short eyes and shorter in long eyes than the composite ALs. The refractive accuracy can be improved in the Hoffer Q, Holladay 1, and SRK/T formulas by changing the composite ALs to the segmented ALs.


Assuntos
Comprimento Axial do Olho , Biometria , Lentes Intraoculares , Óptica e Fotônica , Facoemulsificação , Refração Ocular , Tomografia de Coerência Óptica , Humanos , Comprimento Axial do Olho/patologia , Comprimento Axial do Olho/diagnóstico por imagem , Estudos Retrospectivos , Biometria/métodos , Masculino , Feminino , Tomografia de Coerência Óptica/métodos , Refração Ocular/fisiologia , Implante de Lente Intraocular , Idoso , Pessoa de Meia-Idade , Idoso de 80 Anos ou mais , Acuidade Visual/fisiologia , Pseudofacia/fisiopatologia
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...